i-SMR
Features
01Modular manufacturing and installation
02Land transportation available
1. In-vessel CEDM
Removes the possibility of a control rod ejection accident
2. Boron-free reactor core
System simplification and reducing burdens on maintenance
3. Integrated reactor
Eliminates the possibility of a large break loss-of-coolant accident
4. Canned motor pump
Removes the possibility of a RCP seal LOCA
5. Helical type steam generator
Integrated steam generator within reactor vessel, reducing space and increasing modular fabrication benefits
Specification
Electrical power
170 MWe (per Module)
Total power
680 MWe (4 Modules)
Fuel assembly
UO2 17 x 17
Core damage frequency
1.0e-9 / MY
Construction cost
$3,500 / kWe
Neutron absorber
boron-free
CEDM
In-vessel type
Steam generator
Helical type
Reactor coolant pump
4 (per Module)
Safety system
Fully passive
DC power
Non-safety
Design life
80 years
Seismic design
0.5g
Construction time
24 months (Single Module)